Skip to main content
Firmware Stable

Dashboard

A live overview of the generator system. Connect the controller to the documentation (SXAPI connection) and the readouts below update in real time. Any controller of a pair can be connected — the current and the power are the system totals either way.

System state

The decoded mode and status word:

Generation

Total generated current and power of the system (the raw states are negative while generating — the gauges show them generation-positive):

The gauge ranges (50 A, 2500 W) are display-only defaults — adjust them in this page's source to your system.

Control

The buttons issue the gen commissioning command — a real 0x560 control message, acting on both controllers of a pair. Pick the generation level (0 % starts the engine idling unloaded):

warning

A start request is latched in the firmware and repeats until stopped — closing this page or the connection does not stop the engine. Stop it with the button above (or gen s in any shell).

Preconditions

gen requires CAN as a selected start source (/start_sel = 1 or 3) and a ready driver — a refused start reports the reason. See Commissioning Control.