A live overview of the generator system. Connect the controller to the documentation (SXAPI connection), pick the node, and the readouts below update in real time. Any controller of a pair can be connected — the current and the power are the system totals either way.

The IGNIS tab carries the decoded mode and status word, the followed generation demand, the generation gauges, and the gen commissioning buttons. The Driver and Inputs/Outputs tabs work on any firmware — driver statistics and the controller's own board I/O. Any combination of tabs can be shown at once.

Loading siliDash…
warning

A start request is latched in the firmware and repeats until stopped — closing this page or the connection does not stop the engine. Stop it with the STOP button on the dashboard (or gen s in any shell).

Preconditions

The gen buttons issue a real 0x560 control message and act on both controllers of a pair. gen requires CAN as a selected start source (/start_sel = 1 or 3) and a ready driver — a refused start reports the reason. See Commissioning Control.