Skip to main content
FW version: Stable

Hybrid Accelerator mapping - EXPERIMENTAL

warning

EXPERIMENTAL FEATURE - Use with caution. Functionality may be unstable.

Disambiguation

The term 'throttle' originates from gas/combustion engines, where it refers to a control element for acceleration. As we transition to electric vehicles, we prefer the term 'accelerator'. Both terms can be used interchangeably as synonyms.

Operating Principle

Dynamic accelerator control method:

  • Low speed: Voltage (speed) control
  • High speed: Current (torque) control

Activation

  1. Set /acc/drvmode to 40
  2. Adjust parameters for optimal accelerator response

Configuration Parameters

info

Parameters located in /acc/acc_opts folder

ParameterDescription
thr_curr_offsetVoltage mode current scaling:
0: Current scales with voltage
1: Current remains at 100%, voltage scales with accelerator
CUR_enter_marginCurrent mode activation threshold (when drv_rel_voltage exceeds this value)
VLT_enter_marginVoltage mode activation threshold (when drv_rel_voltage falls below this value)

Status Indicators

VariableDescription
drv_rel_voltageNormalized motor speed (0-1)
drv_rel_currentNormalized motor current (0-1)
1 = phase current equals iref