Operating voltage

The controller implements voltage protection. This protection is hardcoded and cannot be disabled. Also, this protection is faster than ubmin and ubmax limiters. Purpose of this protection is to prevent the controller from damage in case of overvoltage or undervoltage.

  • If the voltage reaches "Critical error voltage", a new log is created and loose your warranty.
  • If the voltage is in the overvoltage "derated" section, the controller will reduce the current output.
  • If the voltage is below the "Treshold voltage", mosfets switching is disabled.
warning

Actual values of the protection differ from controller to controller. Please check the HW documentation of your controller.