Electrical parameters
Tab. 1: Limiting electrical parameters:
| Parameter | Minimum | Maximum | Notes |
|---|---|---|---|
| Number of cells | 4 S | 20 S | balancer variants: (x) max 18S / (y) max 20S |
| Battery voltage | 12 V | 84 V | (specify with order to optimize pricing) |
| Continuous discharge current | ±250 A | DSC port, continuous @ passive cooling | |
| Peak discharge current | ±500 A | DSC port, continuous @ active cooling | |
| Overload threshold | ±600 A | DSC port, internal active limitation | |
| Short-circuit threshold | ±850 A | DSC port, fast-acting protection | |
| Continuous charge current | 100 A | CHG port, continuous @ passive cooling | |
| Peak charge current | 200 A | CHG port, continuous @ active cooling | |
| Charge short-circuit threshold | 220 A | CHG port, fast-acting protection | |
| Continuous balancing current | 10 mA | 84 mA | temperature-protected balancing at all times |
| Short-circuit cut-off time | 1 µs | 5 µs | built-in short-circuit dissipation circuit |
| Sleep consumption | 850 µA | 1150 µA | @ standard sleep (auto sleep/wake control) |
| Deep-sleep consumption | 50 µA | 80 µA | @ storage mode (periodic wake for checkups) |
POWER
| PIN | DESCRIPTION | RATING | PROTECTION |
|---|---|---|---|
| BATT- | pack - | 250 A continuous, 500 A peak | |
| BATT+ | pack + | 84 V (to BATT-) | |
| DISCHARGE- | discharge load - | 250 A continuous, 500 A pulse | bidirectional overload, short circuit to BATT- |
| CHARGE- | charge load - | 100 A continuous, 200 A pulse | bidirectional overload, short circuit to BATT- |
SIGNAL
| PIN | DESCRIPTION | RATING | PROTECTION |
|---|---|---|---|
| cell 1 - | cell 1 minus | 100 mA | |
| cell 2+ ... cell 20 + | cell 2 plus ... cell 20 plus | 100 mA | |
| TS1+ | temperature sensor | 0 - 3.6 V | short circuit to BATT+ |
| TS2+ | temperature sensor | 0 - 3.6 V | short circuit to BATT+ |
| PIN | DESCRIPTION | RATING | PROTECTION |
|---|---|---|---|
| +5V-PROT | +5V supply for the accessories | 5 V, 50 mA max. | PTC-fuse |
| GND | ground reference for the accessories | 50 mA max. | PTC-fuse |
| WS/SDA | data for LEDs / SDA pin of the display | 0 - 3.6 V | |
| SWITCH/SCL | input from the button / SCL pin of the display | 0 - 3.6 V | |
| CONT- | contactor switch output negative / KEY switch input negative | 500 mA, BATT- to BATT+ | |
| CONT+ | contactor switch output positive / KEY switch input positive | 500 mA, BATT+ | fuse 3A |
| CHG DETECT | charger detection signal (active to BATTERY+ or to CONT+) | BATT- to BATT+ |
| PIN | DESCRIPTION | RATING | PROTECTION |
|---|---|---|---|
| CANL | CAN communication low | 0 - 5 V | PTC-fuse, galvanically isolated |
| GNDIO | isolated ground reference | 50 mA max. | galvanically isolated |
| CANH | CAN communication high | 0 - 5 V | PTC-fuse, galvanically isolated |
| VCCIO | supply voltage 5 V | 5 V, 50 mA max. | galvanically isolated |
| TX-ISOL | USART TTL 5 V service communication | 0 - 5 V | PTC-fuse, galvanically isolated |
| RX-ISOL | USART TTL 5 V service communication | 0 - 5 V | PTC-fuse, galvanically isolated |