Skip to main content
Firmware Stable

SX controller

The standard edition of the SX 18 kW controller. Maximum working voltage 84 V. Compact aluminium housing with M6 power terminals and Superseal 1.0 signal connector.

sx-overview

PositionName
1Battery + terminal
2Battery - terminal
3Mounting surface
4Motor phase terminal
5Product label
6Status LED
7Signal connector - Superseal 1.0
8USB cover / Vent plug

Signal part is connected via the signal connector - 7. Battery is connected to M6 terminals - 1, 2, as well as motor phases - 4. The controller should be installed by placing the mounting surface - 3 on a flat metal surface and securing it by four screws. Status LED - 6 indicates error states. USB-C programming connector is under the cover - 8.

Jumpers position

There are also two low profile jumpers under the USB cover. Position of the jumpers and its function is depicted on the picture below.

sx-jumpers

Product identification label

Each product is equipped with an identification label containing pertinent information.

Label

PositionName
1Maximum operating voltage
2Country of manufacture
3SN QR code
4Serial number
5Product Name
6Order code

LED status indicator

The LED status indicator informs about the current state of the motor controller according to table below.

LED stateController condition
Permanently turned OFFController is not powered up
Briefly turned ON and after a few sec OFFController is powered and fully functional
Permanently turned ONController indicates that any of the protections are active. Output current can be limited.
BlinkingController indicates an internal error and is blinking a 16-bit error code. Controller's power stage is deactivated

Accessories

Signal connector

Jumper

Power connectors

  • mating connector: M6 cable lug 10 - 50 mm2 + M6 screw. Terminal thread length is 13 mm, maximum tightening torque is 10 Nm.

Mounting screws

  • 4x M4 or M5 screw. M4 screws are through the heatsink, M5 screws have a thread in the heatsink. Refer to the SX controller drawing.
  • for through-hole mounting, minimum thread depth is 1.5 x screw diameter. Tightening torque depends on the material of the mounting base.

Thermal grease